Which Size AWG Wire Should You Use For 100 Amp Service? (2024)

Which Size AWG Wire Should You Use For 100 Amp Service? (1)

One of the most common questions wire and cable buyers ask is: Which wire gauge to use for 100 amp service, and which type of cable to choose? The truth is that you can use many types of copper and aluminum wire in a 100-amp service. Options include THHN, XHHW, UF-B, USE, and SER.

Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial.

When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can proceed up to 24,000W of electricity.

If the run of the wire is significantly long, such as over 100 feet, you should use a larger size out of the sizes described above to accommodate for voltage drop.

The ground wire size for 100 Amp service is different. You would typically use 8 AWG copper grounding wire or 6 AWG aluminum grounding wire.

Where is 100 AMP Service Used?

Is 100 amp service enough for your home? The answer depends on the size of your home and your appliances.

A 100-Amp service panel is typical for mid-size private houses and apartments with several 240-volt appliances and basic air conditioning. It is quite standard for older homes that have a limited number of appliances.

While 100-amp service is enough for such homes, it is not common for larger houses with the combination of electric and gas appliances and high-power demand. In these houses, 150 amp and 200 amp services are more common. 100 Amp service is not good for houses over 3,000 square feet with central air conditioning or electric heat.

Other basic applications of a 100 amp service panel are detached garages, workshops, agricultural facilities, and temporary power at the construction sites. 100 Amp service may also be used to feed different subpanels and circuit breaker panels in residential, commercial, and industrial buildings. In general, a 100 AMP service is very common, and you can find a 100 amps sub panel everywhere.

Types Of Wire Used in 100 Amp Service

Wires Used in 100 Amp service are different depending on whether it is copper or aluminum wire. Both are perfectly fine to use in these panels. For commercial applications, flame-retardant, plenum or riser-rated, and low-smoke zero halogen cables should be used.

Types of Copper Wire For 100-amp Service Panels

Common types of copper wire used in 100 Amp service are THHN/THWN-2, USE-2 RHH RHW-2, XHHW, type MC cable, copper SER cable, and UF-B cable. The last one is suitable for underground service.

  • THHN/THWN-2 and XHHW-XHHW-2 are used in conduit.
  • USE-2 RHH RHW-2 can be used for underground service entrance applications.
  • Copper SER is a popular choice for panels and subpanels. Make sure to choose the cable with a suitable size of a ground wire.
  • Type MC cable has a protective armor and can be used without conduit.
  • UF-B cable is used for underground service and as a direct burial cable.

Types of Aluminum Wire For 100-amp Service Panels

Aluminum wire for 100 AMP service is just as good as copper wire as long as you choose the correct size.

Common types of aluminum wire used in 100 Amp service are:

Most of these have the same characteristics as their aluminum counterparts, but one cable that is specifically aluminum is 2-2-2-4 Dyke Quadruplex Aluminum Conductor Underground Direct Burial 600V URD.

2-2-2-4 Dyke Quadruplex Aluminum Conductor Underground Direct Burial 600V URD is an all-around great budget-friendly choice for 100 amp service. This cable is suitable for wet and dry applications, as well as for underground service and direct burial.

If you still have questions about different types of electric wiring in service panels, here are a couple of posts to clear things up:

Which Size AWG Wire Should You Use For 100 Amp Service? (2024)

FAQs

Which Size AWG Wire Should You Use For 100 Amp Service? ›

Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial.

What gauge wire do I need for a 100 amp service? ›

Most panels require #2 AWG wire for 100-amp service. You'll need to use #4 AWG wire if the distance between the utility and breaker panel is less than 50 feet. Factors that determine wire size include the distance between the service panel and the electrical load, the surrounding temperature, and the voltage drop.

What is the NEC code for 100 amp service? ›

NEC 230.79(D) For a one family dwelling, the service disconnecting means shall have a rating of not less than 100 amps, 3 wire.

Can 6 gauge wire handle 100 amps? ›

Please note that the ampacity for flexible cords like SO cords is typically less than that for fixed wiring due to the cord's potential exposure to more adverse conditions, like coiling, that impact heat dissipation. As a general rule, a 6 AWG SOOW cord will be rated 45-55 amps max.

Will 4 0 wire fit in a 100 amp breaker? ›

4/0 copper wire is rated for 230 amps. You can use wire larger than the NEC requires, but for 100amps you only need 3awg copper wire or 1awg aluminum wire.

Is 4 AWG good for 100 amps? ›

Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial. When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can proceed up to 24,000W of electricity.

What size wire do I need for 100 amp sub-panel 100 feet away? ›

1) A 100 amp feeder circuit at a distance of 100 ft from the main electrical panel to the sub-panel requires either 2 AWG copper or 1 AWG aluminum for the 2 hot wires and the neutral wire. The 4th wire, equipment grounding conductor needs to be sized as either . 8 AWG copper or 6 AWG aluminum for 100 amps.

What can I run off a 100 amp service? ›

A 100 amp panel can meet the electrical needs of a small or medium-sized property (less than 2,500 square feet) with central air conditioning, gas heating, and several standard appliances.

What is #4 wire rated for? ›

The 4 AWG copper wire amp rating for XHHW-2, USE, RHW-2, and THHN/THWN-2 at 90 °C is 95 Amps. 4 AWG aluminum wire amp rating of RHW, THHW, THWN, and USE at 75 °C is 65 Amps.

What size wire is used for single phase service? ›

Electrical Cables Size & Current Rating Chart
Cross Section (mm2)Approximate Overall Diameter (mm)Current Rating
Single Phase (Amps)
1.52.917.5
2.53.5324
44.432
16 more rows

How many amps will 6 AWG carry? ›

55 AMPS

What gauge wire for 100 amp automotive? ›

Wire Amperage Capacity Chart
Recommended Length and Amperage for Battery Cable while maintaining a 2% or less voltage drop at 12 volts
Battery Cable Size50 Amps100 Amps
4 Gauge (AWG)18.8 ft9.4 ft
2 Gauge (AWG)29.8 ft14.9 ft
1 Gauge (AWG)37.7 ft18.9 ft
5 more rows

Can 8 gauge wire handle 100 amps? ›

The allowable ampacity of an 8 AWG depends on the type of conductor (copper, aluminum), thickness of the conductor, and temperature. According to NEC, the 8 AWG amp rating of copper THHN/THWN-2 at 90 °C is 55 Amps.

What wire do I need for 100 amp subpanel? ›

100amps will require #3 copper and a #8 copper ground wire. Since it is a sub panel, 4 wires are required. 2 hots, a neutral, and a ground wire.

What size wire do I need to run from my house to my shop? ›

It depends on the load, and the distance. Consult and electrician, but for every approx 50ft you need to decrease the wires gauge (this increases its physical size) by at least 1. The standard is 14 gauge for 15a, 12g for 20a, 10g is 30a, 8g is 40 amps.

Is 4 0 good for 100 amp service? ›

#2, #2/0 and #4/0 are popular because of the "whole service derate rule" (310.15B7) which allows those sizes for 100A, 150A and 200A whole services.

What size breaker do I need for a 100 amp subpanel? ›

There is no code that prohibits a 100-amp subpanel from being protected by a 90-amp breaker. Since your plans do not include any electricity-guzzling heavy equipment, your 100-amp subpanel can be supplied with #2 cable if you protect the subpanel with a 90-amp breaker in the main panel.

Is 100 amp service 120 or 240? ›

So a house that needs 80A or more sustained at one time should get 200 A service. By the way, service to residences is always 240 V, not 120 V. So the 100 A or 200 A gets divided between 240 V appliances and two sets of 120 V circuits.

Top Articles
Latest Posts
Article information

Author: Frankie Dare

Last Updated:

Views: 5349

Rating: 4.2 / 5 (53 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Frankie Dare

Birthday: 2000-01-27

Address: Suite 313 45115 Caridad Freeway, Port Barabaraville, MS 66713

Phone: +3769542039359

Job: Sales Manager

Hobby: Baton twirling, Stand-up comedy, Leather crafting, Rugby, tabletop games, Jigsaw puzzles, Air sports

Introduction: My name is Frankie Dare, I am a funny, beautiful, proud, fair, pleasant, cheerful, enthusiastic person who loves writing and wants to share my knowledge and understanding with you.